Angle Two Small Animal Stereotaxic Instrument Stereotaxic myneurolab

Angle Two Small Animal Stereotaxic Instrument Stereotaxic Instrument with Atlas Integration in Computer

The Angle Two small animal stereotaxic instrument enables varying the angle of approach between surgeries without loss of accuracy. Target setting and path of approach are integrated with an onscreen atlas, either mouse or rat or both. Virtual Skull Flat feature corrects for head tilt. Spend less time on each animal, with more accurate results, and vary the angle of approach to avoid confounding action-at-target with path-of-approach.

With no verniers to read or arithmetic to do, risk of human error is greatly reduced. The neuroscientist can improve the rigor and interpretability of stereotaxic research without adding heavy calculations or risk of error to the protocol, and therefore design experiments with fewer animals.

Includes configured computer with software for your choice of mouse or rat installed, manual fine drive for precise transit and positioning. Installed encoders connect to computer allow it to keep track of electrode tip location once shown the position of Bregma.

Video Demonstration for the Angle Two computer-guided stereotaxic.


詳細情報

Fewer animals needed

Reduced risk of human error, and accuracy enhancing features in the software, result in fewer misses so no wasted animals and resulting wasted testing.

Vary angle of approach with no loss of accuracy

Every surgery can be done from a different angle, with no more time required and no loss of accuracy. Avoid confounding of path-of-approach with action-at-target.

Includes on-screen atlas

Click on atlas to define target coordinates. Visual display of path to be followed through brain.

Virtual skull-flat

Instrument measures head tilt from skull flat, and mathematically corrects target position coordinates. No need for trial and error head tilt adjustments.

Save and recall coordinates sets

For multiple user labs, store the coordinate set in an on-screen icon at the bottom. Recall by clicking on the icon when in Set Target mode.

Manual Fine Drive

Low mounted manual fine drive on the DV axis helps avoid hand transmitted vibration during operation of the DV drive, and makes it easy to avoid overshoot.


loading...

製品の注文はこちら

商品番号 商品名 詳細を表示 サイズ 数量
39464601 Angle Two™ Stereotaxic Instrument f/Rat 1 Piece 1
39464603 Angle Two Stereotaxic-220 V for Rat 1 Piece 1
39464610 Angle Two™ Stereotaxic for Mouse 1 Piece 1
39464613 Angle Two Stereotaxic-220V for Mouse 1 Piece 1
39464671 Angle Two™Dual Stereotaxic Mouse, 120 V 1 Piece 1
39464676 Angle Two™ Dual Stereotaxic Mouse,220 V 1 Piece 1
39464651 Angle Two™Dual Stereotaxic f/Rat, 120 V 1 Piece 1
39464650 Angle Two™Dual Stereotaxic f/Rat, 220 V 1 Piece 1
39462948 Gas Adaptor Plate f/ Adult Mice 1 Piece 1
39463023 Gas Anesthesia Adaptor for Rat 1 Piece 1
39464691 Video Microscope Two for Angle Two 1 pieces 1